Page 10-692
HYB-LINE (Hybrid Line) 
10
Hybrid Line Lamp Updates Test (#60)
For this test, the software lights the lamps on the terminal based on the status 
record contained in the processor. The lamp updates run only if the station is 
in-service.
1,2,3
FAIL
No response was received within the allowable time period on one of the 
transmissions to the terminal. This indicates that something is wrong with 
the data link to the voice terminal. This could be a sleeping set problem or 
it may be due to wiring or an unplugged or defective set.
1. Check for errors in the error log, for example, error 1537.
2. Remotely issue the 
busyout
 and 
release busy
 commands, and run 
the short test sequence on the port to check for other errors 
associated with the port or terminal.
3. Check the wiring to the set if it appears that the terminal is not 
responding to any tests; otherwise, replace the terminal and rerun the 
test.
4. If the test still fails, replace the circuit pack and reconnect the original 
terminal.
PASS
Hybrid Line Remote Digital Loop Around Test passed. The hybrid circuit 
pack is sending and receiving proper messages to and from the voice 
terminal.
1. If problems still exist, investigate using other circuit pack tests and by 
examining the station, wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-230.
TEST #59 Hybrid Line Remote Digital Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page