DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-696
HYB-LINE (Hybrid Line) 
10
Hybrid Line Ringer Update Test (#62)
In this update, a "ringer on" or a "ringer off" message is sent to the firmware to 
start and stop the ringer on the set.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS
Hybrid Line Audits Test passed.
1. Although this test always return a PASS result, it may enter Error Types 
257 or 513 into the Error Log. To determine if there are any problems 
that don’t show up in the test result, look for these error types in the 
Error Log.
2. If these errors appear in the Error Log, or if user complaints still exist, 
investigate by using other circuit pack tests, and by examining the 
station, wiring, and connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-232.
TEST #61 Hybrid Line Audits Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page