Maintenance Object Repair Procedures 
Page 10-714
ISDN-PLK (ISDN-PRI Signaling Link Port) 
10
e. “Transmit FIFO Overflow error” This error indicates that the circuit pack is 
having problems transmitting data to the Packet Bus, thus affecting the 
conveyance of signaling information over the D-channel. Specifically, this 
error occurs when the Packet Bus transmit buffers overflow. This condition 
probably indicates a hardware problem.
The actual alarming level depends on the options chosen via the 
set 
options
 command on the G3-MT terminal. ISDN-PRI Signaling Link Port 
alarms are treated as Station alarms, and their default alarming option is to 
downgrade all alarms to Warning. The value shown in the preceding table 
indicates the normal, unfiltered case (option "y" on the 
Set Options
 form).
f. “Bad DLCI error” This error occurs when a LAPD frame is received across 
the DS1 facility which contains a DLCI which does not have a valid entry in 
the on-board translation memory. This error normally indicates an 
off-board problem usually related to a broken endpoint or a state 
mismatch between a remote endpoint and the local call processing 
software. Maintenance will not start any testing or generate any alarms in 
response to this error.
g. “Receive FIFO Overflow error” This error occurs when the circuit pack 
detects an overflow of its receive buffers. If it occurs frequently, it may 
indicate a LAPD parameter mismatch between the two end-points of a 
packet switched connection. LAPD should be able to recover from this 
problem, but it may degrade the performance of the Packet Bus. 
Maintenance will not start any testing or generate any alarms in response 
to this error.
h. This error occurs when the 
Signaling Port Packet Bus Loopback Test 
(#939)
 fails. Run the long test sequence and pay particular attention to the 
results of 
Test #939
.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. REMINDER: The command line entry to test the 
ISDN-PLK MO is: 
test port PCSSpp (sh or l)
, where ‘pp’ is ‘24’ for 24-channel 
interfaces, and ‘16’ for 32-channel interfaces.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Signaling Port Bus Loopback Test (#939)
X
D
Signaling Link Board Check (#643)
X
X