Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-731
ISDN-SGR (ISDN-PRI Signaling Group) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This switch sent a message to the far-end switch or terminal adapter, and 
the far-end did not respond in the allotted time. Possible causes include 
link failure and congestion or outage at the far-end. The Aux Data field 
contains Layer 3 protocol information used by internal counters.
If no other symptoms are not present, no action is required. If Layer 3 
communication is down, there should be indications in the form of alarms 
and errors for link components. Check out other errors against ISDN-SGR, 
ISDN-TRK, and other hardware components on the link.
1.
Run the Short or Long Test Sequence. Refer to the appropriate test description and follow the 
recommended procedures.
Table 10-241.
ISDN-PRI Signaling Group Error Log Entries
Error 
Codes
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
test sig-group 
<group>
1 (a)
Any
none
257 (b)
Any
none
test sig-group 
<group>
513 (c)
Any
none
test sig-group 
<group>
769
Any
Primary Signaling 
Link Hardware 
Check (#636)
test sig-group 
<group>
1025
Any
Secondary Signaling 
Link Hardware 
Check (#639)
test sig-group 
<group>
1793 (d)
Any
Layer 2 Status (Test 
#647)
WARNING
OFF
test sig-group 
<group>
2049 (e)
Any
Layer 2 Status (Test 
#647)
WARNING
OFF
test sig-group 
<group>
2305 (f)
Any
Remote Layer 3 
Query (Test #637) 
MINOR
OFF
test sig-group 
<group>
3585 (g)
port 
number
none
none
3840- 
3928 (h)
port 
number
none