Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-741
ISDN-SGR (ISDN-PRI Signaling Group) 
10
Secondary Signaling Link Hardware Check (#639)
The ISDN-PRI Signaling Group D-Channel port depends on the health of the 
DS1/UDS1 Interface circuit pack on which it resides. This test will fail if there are 
problems with either the ISDN-PRI Primary D-channel port or the DS1/ UDS1 
circuit pack. If there are problems with the ISDN-PRI Secondary Signaling 
Channel port (ISDN-LNK or ISDN-PLK), also investigate the DS1/UDS1 circuit 
pack.
Figure 10-56.
Secondary Signaling Link Hardware Check for PRI over PI 
(Test #639)
PASS
A message was composed and sent to the Far-end switch. The ISDN PRI 
specification allows up to two minutes for a reply.
1. Check the Error Log for ISDN-SGR (ISDN-PRI Signaling Group) for 
errors of type 2305 for evidence of a Remote Layer 3 Query failure. If no 
new errors were logged since this test was run, then this switch and the 
Far-end switch processor can exchange call control messages.
2. If there is still a problem with a particular DS1 ISDN Trunk or PRI 
Endpoint Port (B-channel), busyout the trunk or port and run the long 
test sequence, paying particular attention to the results of Test #258 
(ISDN Test Call).
Table 10-244.
TEST #637 Remote Layer 3 Query  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page
PI
TDM
BUS
DS1/UDS1
TO FAR-END
SWITCH HARDWARE
(TN765)
CIRCUIT
PACK CIRCUIT
PACK
INTERFACE