Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-779
MAINT (EPN Maintenance Circuit Pack) 
10
Since the EPN Maintenance circuit pack supports environmental maintenance in 
the EPN, trouble with the EPN Maintenance circuit pack can cause environmental 
maintenance to falsely detect problems. These environmental MOs include 
DC-POWER, EMG-XFER, EXT-DEV, and CUST-ALM.
Since communication to the EPN Maintenance circuit pack flows through the 
SW-CTL (Switch Control) and the EXP-INTF (Expansion Interface) circuit packs, 
any problems with these MOs can prevent communication with the EPN 
Maintenance circuit pack.
If a repair procedure calls for the EPN Maintenance circuit pack to be replaced, 
and the EPN has redundant Expansion Links, use the following procedure to 
prevent an Expansion Links switch when the new EPN Maintenance circuit pack 
is plugged in.
1. Determine the Standby Expansion Links by using the 
status system
 
command.
2. Busyout the Standby Expansion Links by issuing the 
busyout board 
PCSS
 command where PCSS is the 4-character circuit pack address of 
the Expansion Interface circuit pack in the EPN on the Standby link.
3. Replace the EPN Maintenance circuit pack.
4. Release the Standby Expansion Links by issuing the 
release board PCSS
 
command, where PCSS is the 4-character circuit pack address of the 
Expansion Interface circuit pack in the EPN on the Standby link.
Error Log Entries and Test to Clear Values
Table 10-258.
EPN Maintenance Circuit Pack Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test maintenance sh r 1
1 (a)
0
1
EPN Maintenance Circuit 
Pack Reset Test (#306)
MINOR
ON
test maintenance l
513 (a)
0
1
MGR I Channel Loop Test 
(#228)
MINOR
ON
test maintenance sh r 3
769 (b)
Any
Sanity Handshake Test 
(#106)
1537 (a)
0
1
Sanity Maze Test (#303)
MINOR
ON
test maintenance sh r 3
2561 (a)
0
1
Sanity Handshake Test 
(#106)
MINOR
ON
test maintenance sh r 3
Continued on next page