Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-788
MAINT (EPN Maintenance Circuit Pack) 
10
EPN Maintenance Circuit Pack Sanity Maze Test 
(#303)
The EPN Maintenance circuit pack processor has direct access to special 
registers in the EPN Maintenance circuit pack. These registers are tied to such 
things as the Expansion Interface circuit pack reset leads and Carrier Port Power 
Unit reset leads (which enable the EPN Maintenance circuit pack to recycle 
carriers). To prevent an insane EPN Maintenance circuit pack from inadvertently 
controlling these external devices, a special interface called the Sanity Maze is 
provided that must first be navigated by the EPN Maintenance circuit pack 
FAIL
The on-board circuitry associated with the Standby serial link is defective. 
Since the EPN Maintenance circuit pack reported this failure, the on-board 
circuitry associated with the Active serial link is functional.
1. This test checks the circuitry on the EPN Maintenance circuit pack 
associated with the Standby Expansion Interface link.
In a switch without duplicated Expansion Links, current service is not 
affected because the circuitry failing is not being used. Nevertheless, 
a Minor alarm remains in the Alarm Log against MAINT. Therefore, the 
EPN Maintenance circuit pack must be replaced.
In a switch with duplicated Expansion Links, service is not affected as 
long as you DO NOT SWITCH LINKS; otherwise, the connection to the 
EPN Maintenance circuit pack is lost. Losing the EPN Maintenance 
circuit pack connection means loss of the EPN Manager I (G1) or 
G3MT and EPN Environment maintenance. If an Expansion Links 
switch does occur, the software probably switches the links back, 
based on the relative health of each link. The EPN Maintenance circuit 
pack must be replaced to correct this problem.
PASS
The on-board circuitry associated with both Expansion Interface circuit pack 
serial links is good. If there is still a problem communicating with the EPN 
Maintenance circuit pack, check the following:
1. The cable comprising the serial link (B carrier Expansion Interface circuit 
pack to EPN Maintenance circuit pack only) may be defective.
2. The EPN Maintenance circuit pack may actually be defective.
NOTE:
This test may not be 100 percent accurate.
3. The Expansion Interface circuit pack on the Standby link may be 
defective.
Table 10-262.
TEST #229 Serial Channel Local Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation 
Continued on next page