Maintenance Object Repair Procedures 
Page 10-822
MET-LINE (MET Line) 
10
MET Line Station Audits Test (#61)
This is a series of three tests that are classified as audits. These audits abort if 
attempted on an out-of-service station. The tests are as follows:
Switchhook Audit—This is an update of the SPE records according to the 
circuit packs’ records.
Bad Scan Inquiry—A message is sent uplink that contains a count that is 
generated due to certain events relating to the link conditions. This is an 
indication of data transmission problems between the MET Line circuit 
pack and the voice terminal.
EPF Inquiry—The status of the EPF is sent uplink. Possible conditions are: 
EPF-on-ok, EPF-off, EPF-no-load, and EPF-on-overcurrent.
Although this test will never actually return a fail result (except for the internal 
system error), it is possible that it will enter error types 257 (over current) or 513 
(open circuit) into the error log. To determine if there are any problems that do 
not show up in the test result, look for these error types in the error log. If these 
errors appear in the error log or if user complaints still exist, investigate by using 
other circuit pack tests and by examining the station, the wiring, and the 
connections.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
check to ensure that there is a valid board inserted.
Table 10-275.
TEST #60 MET Line Station Lamp Updates Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page