DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-827
MIS (Management Information System) 
10
MIS (Management Information 
System)
The Management Information System (MIS)/Call Management System (CMS) MO 
is used only for administering MIS translations, such as trunks and stations. 
There are no hardware failures associated with this MO.
NOTE:
To diagnose MIS link hardware errors and alarms, see PI-LINK (Processor 
Interface Link) and PI-SCI (System Communication Interface) maintenance 
information.
The MIS/CMS is an adjunct processor that collects ACD data sent from the 
system. To change MIS translations, a system administrator must first enter a 
busyout mis
 command at the terminal. When the MIS is busied out, the system 
stops sending ACD data to the MIS, and a Warning alarm is raised. When 
finished, a 
release mis
 command should be entered at the terminal. This clears 
the Warning alarm and allows the switch to send ACD data to the MIS.
Error Log Entries and Test to Clear Values
Note:
a. When the 
busyout MIS
 command is issued, no data is sent to the 
MIS/CMS regardless of the link state. To allow data to be sent to MIS/CMS, 
release mis
 command must be issued from the terminal.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
MO Name (in 
Alarm Log
Alarm 
Level
Initial Command to Run
Full Name of MO
MIS
WRN
release mis
Management Information System
Management Information System Error Log Entries
Error Type
Aux Data
Associated Test
Alarm Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
release mis
18(a)
0
busyout mis
WARNING
ON
release mis