DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-872
M/T-ANL (Maintenance/Test Analog Port) 
10
Clear Error Counters (#270)
The ports on the Maintenance/Test circuit pack continually run self-tests, 
whenever the port is idle. The Angel uses a counter so that the Background 
Maintenance Failure message is only sent uplink once (this keeps a failed 
port/circuit pack from flooding the SPE with a string of messages). Many circuit 
packs have counters in the Angel firmware. These counters are used so that 
Control Channel Message Set (CCMS) messages are not continuously sent 
uplink. Using this method, the message will be sent once, when the counter 
reaches some preset threshold, and then not sent again until the counter is 
cleared. This test is used to clear the counter, so that if the port continues to fail 
during or after SPE-demanded testing, the Angel will send a message to indicate 
that fact.
This test is only used to send a message to the Angel on the Maintenance/Test 
Circuit Pack. Therefore, this test should never abort or fail.
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Analog Port maintenance software 
and call processing agree on the on-/off-hook status of the Maintenance/Test 
Analog Port.
Table 10-293.
TEST #270 Clear Error Counters 
Error 
Code
Test Result
Description/ Recommendation
PASS
The message to clear the Maintenance/Test circuit pack’s 
counter for Background Maintenance Failures has been sent.
Continued on next page