DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-881
M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
Digital Port Loop Around Test (#13)
This test is a modification of the Voice and Control Channel Local Loop Test used 
by Digital Station (DIG-LINE) maintenance. This test does not perform the control 
channel and secondary information channel loop around tests as described for 
DIG-LINE, as these data paths do not exist for the Maintenance/Test Digital Port. 
The primary information channel is tested by first looping back the data channel 
onto the TDM Bus, and then sending a digital count from the Tone-Clock circuit 
pack and receiving the same digital count with a general purpose tone detector. 
A conference test is done next for the primary information channel. This test is the 
same as Conference Test #6.
1004
ABORT
The port has been seized by a valid ISDN-PRI test call. Use the 
list 
isdn-testcall
 command to determine which call is using the port (from 
the M/T Port column). Either wait for the test call to complete (as 
indicated in the Start Time and Duration fields of the above display), or 
abort the test call with the 
clear isdn-testcall tg/mem
 command, where 
tg/mem is determined from the B-channel field of the above display.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This 
causes noisy and unreliable connections.
1. If the remaining ports are currently not in use (yellow LED is off), try 
to reset the circuit pack. Then repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported 
troubles on this port should be investigated using other port tests and 
by examining station, trunk, or external wiring.
Table 10-296.
TEST #9 NPE Cross Talk Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page