DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-887
M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software 
and call processing agree on the on-/off-hook status of the Maintenance/Test 
Digital Port.
1138
ABORT
This test does not run on Port 3 of the Maintenance/Test circuit pack. 
This test runs only on Port 2. Look at the results of the Digital Port Sanity 
Test for Port 2.
1. Run the command again for Port 2 via the 
test port PCSS02
 or 
test 
port PCSS02 l
 command.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
2100
ABORT
System resources required to run this test are not available.
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to fail, escalate the problem.
50
FAIL
The switch was unable to communicate with the port circuitry used for 
digital trunk testing.
100
FAIL
Data was not sent from Port 2 to Port 3 successfully in asynchronous 
mode.
101
FAIL
Data was not sent from Port 3 to Port 2 successfully in asynchronous 
mode.
102
FAIL
Data was not sent from Port 2 to Port 3 successfully in synchronous 
mode.
103
FAIL
Data was not sent from Port 3 to Port 2 successfully in synchronous 
mode.
1. Reset the circuit pack via the 
busyout board PCSS
reset board 
PCSS
release board PCSS
 command sequence.
2. Test the port again via the 
test port PCSS02 l
 command.
3. If the test fails again, replace the circuit pack.
PASS
The Maintenance/Test Digital Port digital trunk testing capability is 
operating correctly.
Table 10-299.
TEST #161 Loop Around Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page