Routine Maintenance Procedures 
Page 5-56
System Features 
5
Figure 5-8.
Processing of ISDN-PRI Problems (Page 2 of 2)
Troubleshooting PRI Endpoint Problems
The following flowchart, 
 and 
, defines a layered approach 
when troubleshooting PRI endpoint problems. Since a problem at a lower layer 
affects upper layers, layers are investigated from low to high. In the flowchart, the 
DS1 facility is layer 1, the TN765 Processor Interface is layer 2, and the ISDN 
trunks are layer 3.
PAGE
YES
END
A
FROM
1
ARE
THERE
TRANSIENT
PROBLEMS MAKING
ISDN-PRI
ARE
THERE BIT
ERRORS OVER
HAS A
SYNCHRONIZATION
SOURCE BEEN
SYSTEM SWITCHING
IF PROBLEMS
STILL EXIST,
THEN ESCALATE
COMPARE INDICATED
FACILITY TO RECORD
OF PREVIOUS PROBLEMS
ARE BIT
ERRORS OCCURRING
MORE FREQUENTLY
THAN PREVIOUS
RECORD INDICATED
FACILITY AND, IF THIS
CONTINUES TO OCCUR,
CONTACT FACILITY OR
EXTERNAL EQUIPMENT
THE TI FACILITY?
UNSTABLE?
AWAY FROM IT?
NO
YES
SEE DS1-BD MO FOR
REPAIR PROCEDURES IF
SYNC PROBLEM IS DUE
TO SLIPS. OTHERWISE,
FOLLOW REPAIR
PERFORM AN IN-DEPTH
ANALYSIS OF T1
FACILITY INCLUDING:
TRANSMISSION FACILITY,
EXTERNAL EQUIPMENT
AND ANY OTHER
NOISE-PRODUCING
EQUIPMENT.
REFER TO AT&T PRACTICE
855-351-101 ISSUE 8,
JANUARY 1987. THIS
DESCRIBES T1 CABLING TO
(DACS, CSUs, ETC.,)
CSUs, ETC, IN DETAIL
YES
NO
NO
NO
YES
END
CALLS
SEE SYNC MO
HISTORY
PROVIDER. THEN ESCALATE
PROCEDURES FOR
SYNC MO
USE LIST
MEASUREMENTS
COMMAND