DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-922
PDMODULE, TDMODULE (Data Module) 
10
Data Module Internal Loop Around Test (#175)
This test verifies that a data message can be sent from the PBX, through the 
building wiring, through an internal looparound path in the data module under 
test, and back to the PBX. 
 shows the hardware configuration used 
for this test.
5
ABORT
Ringer update aborted (data module not in the in-service state).
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring, check for 
faulty wiring, check for faulty data module.
3. Retry the command at one-minute intervals a maximum of five times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit pack and 
repeat the test.
6. If the test continues to abort, escalate the problem.
6
ABORT
Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at one-minute intervals a maximum of five times.
3. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the allowable time 
period.
FAIL
Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to fail, escalate the problem.
PASS
Data Module Audits passed. This digital port circuit pack is functioning 
properly.
1. If complaints still exist, investigate by using other port tests, and by 
examining the data module options, wiring, and connections.
Table 10-309.
TEST #17 Data Module Audits Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page