Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-930
PE-BCHL (PRI Endpoint Port) 
10
Service States
In-Service (INS)
The B-channel is in its normal operating state.
Out-of-Service/Far-end (OOS/FE)
A B-channel is initialized to this state when administered. The switch 
sends messages to the far-end terminal adapter to negotiate the 
B-channel into service. If the far-end terminal adapter does not respond to 
the messages within a certain time period, the service state remains 
out-of-service, and maintenance periodically resends the messages. The 
port is unusable for calls incoming to the switch and outgoing to the 
terminal adapter (although other ports in the PRI Endpoint can still be 
used for incoming and outgoing calls).
Out-of-Service/Near-end (OOS/NE)
This is the state of the port whenever one of the following is true: a 
hardware failure exists on the signaling link, the NPE Crosstalk Test fails, 
or the port is busied out by system technician. In this state, the port is 
unusable for calls incoming to the switch or outgoing to the terminal 
adapter (although other ports in the PRI Endpoint can still be used for 
incoming and outgoing calls). No messages are sent to the far-end 
terminal adapter until the signaling link comes back into service or until the 
port is released by system technician.
Maintenance/Far-end (MTC/FE)
This state is reached when the far-end terminal adapter does not respond 
to messages sent over the signaling link for a particular port after a certain 
amount of time. This state is different from OOS/FE inasmuch as the 
signaling link must be up initially and the B-channels must be in-service. 
The switch periodically sends messages to the far-end terminal adapter in 
an attempt to negotiate the port (B-channel) into service. The port is 
unusable for calls outgoing to the terminal adapter. However, the port 
services incoming call requests from the far-end (although other ports of 
the PRI Endpoint can still be used to answer calls incoming to the switch 
or to place outgoing calls to the terminal adapter). Note that transitions 
into MTC/FE do not drop stable calls. Therefore, if the service state 
changes from in-service to MTC/FE, stable calls are unaffected.
Maintenance/Near-end (MTC/NE)
The port (B-channel) is in this state if the signaling link (PI-LINK) is busied 
out by system technician. The port (B-channel) is also temporarily in this 
state if the system technician has issued a 
test port PCSSpp l
 or a 
test 
pri-endpoint <extension> l
 command. Note that transitions into MTC/NE 
do not drop stable calls. Therefore, a system technician-demanded 
busyout link lnk-no
 command does not drop stable wideband calls. In 
this state, the B-channel is not usable either for new calls incoming to the 
switch or for new calls outgoing to the terminal adapter.