Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-953
PI-LINK (Processor Interface Link) 
10
PI-LINK (Processor Interface Link)
NOTE:
Reference lnk-no using the 
display communication-interface links
 
command.
The Processor Interface (PI) Communication Link is the physical link that 
connects DEFINITY to an adjunct such as AUDIX, another node in a DCS 
network, or an ISDN-PRI connection. These links are either X.25 (DCS, AUDIX, or 
MIS) or ISDN (ISDN-PRI). The system supports up to four of these links per 
TN765 Processor Interface circuit pack. PI-LINK maintenance actually monitors 
several hardware devices: Processor Interface ports, TN754 or TN784 Digital 
Line ports, PDMs, TDMs, MTDMs, MPDMs, and DS1 facilities. Henceforth, "data 
module" refers to either PDM, TDM, MPDM, or MTDM. 
In much of the following 
link documentation, the repair procedures described mention various 
hardware configurations. Choose the procedure appropriate to your 
configuration.
The Processor Interface circuit pack provides an EIA connection. This 
connection can be administered only on Link 1 in a system without High or 
Critical Reliability. The EIA port is used when an adjunct (AUDIX, for example) is 
near (less than 25 feet) or further if a modem is used. The EIA port can also be 
used to connect two PBXs together via DCS. The EIA port cannot be used in a 
High or Critical Reliability system.
The Processor Interface Link can be in three different states. These states can be 
seen using the 
status link lnk-no
 system technician command. If the link is in a 
maintenance busy
 state, then the system technician had instructed the 
Processor Interface to be in maintenance busy by entering the 
busyout link 
lnk-no
 command or the Processor Interface Link is not established and 
maintenance is trying to bring it up. This probably means that an error condition 
is occurring somewhere on the link that keeps the link from being logically 
connected and carrying data. If the link is busied out, then it can be put back into 
service by issuing a 
release link lnk-no
 command. This restarts the link. If the 
link is for DCS, then it may speed the recovery of the link if 
busyout link lnk-no
 
and 
release link lnk-no
 are executed on the switch that is establishing the 
connection (see the Communication-Interface Links form). The link can be in a 
disconnected
 state if the link cannot be started up. In this case, maintenance 
tries to establish the link periodically. If the link is up and data is being sent 
successfully, then the link is in the 
in-service
 state.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
PI-LINK
MINOR
test link lnk-no l
Processor Interface Link
PI-LINK
WARNING
test link lnk-no l
Processor Interface Link