Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1003
PKT-CTRL (Packet Control Circuit Pack)
10
Packet Control Reset Test (#586)
This test resets the Packet Control circuit pack, downloads Packet Control circuit
pack firmware form tape, and then causes the Packet Control circuit pack to
begin operation.
pack firmware form tape, and then causes the Packet Control circuit pack to
begin operation.
!
WARNING:
This test is destructive and disrupts service when run on the Packet Control
circuit pack in the Active SPE. This test is not destructive when run on the
Packet Control circuit pack in the Standby SPE of a High or Critical
Reliability system. When this test is run on the Packet Control circuit pack
on the Active SPE, the "busyout packet-control C" command must be
executed first. Once testing has been completed, a busied-out Packet
Control should be released via the release packet-control C command.
circuit pack in the Active SPE. This test is not destructive when run on the
Packet Control circuit pack in the Standby SPE of a High or Critical
Reliability system. When this test is run on the Packet Control circuit pack
on the Active SPE, the "busyout packet-control C" command must be
executed first. Once testing has been completed, a busied-out Packet
Control should be released via the release packet-control C command.
1-3
FAIL
Maintenance was unable to establish a loop around link from the Packet
Control circuit pack back to itself, or was unable to receive the data that was
sent out over one side of the loop around link.
Control circuit pack back to itself, or was unable to receive the data that was
sent out over one side of the loop around link.
1. Issue
test packet-control C short
command to retry the test.
2. If the same error code is observed, maintenance software automatically
escalates the testing. No specific action is required.
PASS
The Packet Control circuit pack can send and receive data correctly.
Table 10-343.
TEST #585 Packet Control Loop Around Test —
Continued
Error
Code
Code
Test
Result
Description/ Recommendation
Continued on next page