DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Routine Maintenance Procedures 
Page 5-67
Troubleshooting Multimedia Call Handling (MMCH) 
5
audio conference. If the system does not switch broadcasters even after the 
current broadcaster has muted, check the conference administration using the 
display conference X
 command to ensure that the conference is in 
voice-activated mode. Also verify that parties who were speaking are valid video 
sources as described in the “
” section above.
The See-Me feature (MCV) can also cause VAS to “lock-up.” An endpoint can 
activate MCV to force their site to become the broadcaster. If they do not disable 
the feature when finished, the system remains in this mode indefinitely. 
Beginning with Release 3.0, the 
status conference X
 command shows that MCV 
is in effect by displaying 
av
 in the Video Status (Vs) column. Page 3 of the Status 
Conference X Endpoint Y form also has a 
Broadcaster
 field that indicates MCV 
is in effect with (SEE-ME) as the broadcaster. The same scenario can occur in a 
CHAIR or UCC-controlled conference with a designated broadcaster. In this 
situation the CHAIR/UCC has not released the designated broadcaster and 
returned to VAS mode. If there is a UCC-designated broadcaster, 
status 
conference X
 indicates a Video Status of 
u
. Also, for UCC rollcall the return 
video may appear to be stuck. Check the Video Status for an “
R
,” indicating 
rollcall.
If none of the examples above appears to be the cause, and if the room was 
quiet, all speakers are valid video sources, the conference is voice-activated, 
and the speaker can be heard, then escalate the problem.
Video Never Switches to a Particular Party
Description
Verify that the endpoint is a valid video source as described in the “
” section above. If it is, then the audio from the endpoint 
may not have sufficient voice signal for the hardware to determine the parties at 
the endpoint are speaking. Check the 
Talk
 field on page three of the Status 
Conference X Endpoint Y form to see if the
 talking bit
 is 
y
. Next, check the 
audio by standing adjacent to the microphone and speaking at a normal level. 
Solution
If the audio is not muffled:
1. Use the 
status conference
 command to determine which port on the 
TN788B (VC board) is connected to this endpoint.
2. Check the VC (TN788B) board using the 
test board xxyy long
 command.
3. Drop the call.
4. Find another available port, then:
a. Busyout the port to which the endpoint was connected.