Page 10-1038
PR-MAINT (Maintenance Processor [TN790 RISC Systems]) 
10
MTP Reset Test (#101)
This test is destructive.
The test resets the Maintenance Processor. The destructive nature of this test 
causes the following:
System Access Terminal to log off
DCE port to terminate data transmission
Any current memory card access to terminate and also to tear down any 
remote access INADS connection
Table 10-354.
TEST #101 MTP Reset Test 
Error 
Code
Test 
Result
Description/ Recommendation
100
ABORT
The requested test did not complete within the allowable time period.
1. Retry the command.
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
2500
ABORT
Internal system error
1. Retry at 1-minute intervals a maximum of 5 times.
1196
FAIL
The MTP did not respond to being reset.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, replace the Processor circuit pack.
1197
FAIL
The Maintenance Processor was reset, but it responded with a NOT PASS 
status, indicating that it did not pass initialization correctly. The MTP is not 
functioning correctly. The system continues to function. Environmental 
monitoring is lost, as is communication with the Standby Processor.
1. Retry at 1-minute intervals a maximum of 5 times.
2. If test continues to fail, replace the Processor circuit pack.