Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1041
PR-MAINT (Maintenance Processor [TN790 RISC Systems]) 
10
MTP Analog Loop Around Test (#103)
This test is a nondestructive test. The test does a loop around by using the MTP 
INADS channel. Test data is sent through the modem out toward the INADS 
trunk. The data is looped around before the actual trunk, and it comes back into 
the on-board modem. The data is then verified for integrity. The internal modem 
is tested when the internal modem is selected. The external modem is tested 
when the external modem is selected.
When an external modem is administered in place of the internal modem, the test 
loops data in the MTP DUART ahead of the connection to the external modem. 
This test also causes the MTP DUART to verify that 
Clear-To-Send (CTS)
 is 
being supplied by the modem.
NOTE:
The test does not send any data onto the INADS trunk. However, to pass, 
the test does require the trunk to be present
PASS
MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact the system, 
check with the local Central Office for problems with the INADS trunk, 
and verify that the INADS number is correct. Approved external 
modems with factory default settings are expected to work if 
administered correctly using the 
change system-parameters
 
command.
Table 10-356.
TEST #103 MTP Analog Loop Around Test 
Error 
Code
Test 
Result
Description/ Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1000
ABORT
System software resources required for this test are not available.
1. Retry at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 10-355.
TEST #102 MTP Outpulse Relay Test  — 
Continued
Error 
Code
Test Result
Description/ Recommendation
Continued on next page