DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1063
PR-MEM (TN790 RISC Memory) 
10
Error Log Entries and Test to Clear Values
Notes:
a. This error (3) indicates that a software patch has been applied and either 
the software patch is bad or was installed incorrectly.
1.Back out the software patch and run the 
test memory UUCS long
 
command to verify that the problem has been cleared.
2.If the PBX system is equipped with High Reliability or Critical Reliability 
option (i.e. with duplicated SPEs), and this error occurs, a SPE 
interchange will occur if the health of the standby SPE permits the 
interchange.
b. The following Aux Data indicate SIMM Failures
1.SIMM A
2.SIMM B
3.SIMM A & SIMM B
4.SIMM C
5.SIMM A & SIMM C
6.SIMM B & SIMM C
7.SIMM A, SIMM B, & SIMM C
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Table 10-369.
Memory Error Log Entries
Error 
Type
Aux Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test memory a/b l r 1
1
Any
Flash Memory 
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
3(a)
Any
Flash Memory 
Checksum Test (#86)
MAJOR
ON
test memory a/b l r 5
1025
Any
Memory Parity Error 
Detection Test (#87)
MINOR
ON
test memory a/b r 3
1281
Any
Memory Burst Read 
Test (#908)
MAJOR
ON
test memory a/b l r 2
1793
Any (b)(c)
Read All Memory (#85)
MAJOR
ON
test memory a/b l r 1
2049(d)
Any (b)(c)
Memory Functional 
Test (#332)
MAJOR
ON
test memory a/b l r 1