DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1099
RING-GEN (Analog Ring Generator) 
10
Analog Ring Generator Initialization Test (#117)
The TN768, or TN780 will report an error to the system software if the ringing 
voltage falls to low (only if system software has made a request to the TN768, or 
TN780 to monitor the voltage). The Analog Ring Generator Initialization Test 
sends a request to the TN768, or TN780. If there are redundant tone/clock circuit 
packs in the port network, then the request is sent only to the active tone/clock.
Analog Ring Generator Query Test (#118)
This test requests the Active Tone-Clock circuit pack to check the ringing 
voltage. The tone/clock circuit pack replies with PASS if the ringing voltage is 
adequate to ring the analog phones. If not, the active tone/clock circuit pack 
replies with a FAIL. The Analog Ring Generator Query Test then reports the 
result.
Table 10-390.
TEST #117 Analog Ring Generator Initialization Test 
Error 
Code
Test 
Result
Description/ Recommendation
1
1000 
1001 
1003 
1115 
2012 
2100
ABORT
The system software is unable to determine the active tone/clock circuit 
pack, unable to allocated the resources necessary to run the test, or unable 
to send a down link message.
1. Wait for the green LED on the active tone/clock to go out; use the 
status 
port-network
 command to determine the active Tone/Clock circuit 
pack. 
2. Rerun the test. If the test aborts again, refer to TDM-CLK Maintenance 
documentation.
2000
ABORT
Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all other Tone/Clock 
problems first. 
2. Rerun the test.
1005
ABORT
The tone/clock is unable to read the analog ringing voltage level when the 
tone/clock is in the Processor Interface slot. This test is not available for the 
Processor Port Network in this configuration.
PASS
The active Tone/Clock has successfully been enabled to monitor the ringing 
voltage level.
Continued on next page