Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1105
S-SYN-PT (Speech Synthesis Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has 
occurred. Refer to Test #168 for repair procedures.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
Speech Synthesis Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1(a)
17672
None
18
0
busyout port PCSSpp
WARNING
OFF
release port PCsspp
130(b)
None
WARNING
ON
test port PCSSpp sh
257
Speech Synthesis 
PSS Handshake Test 
(#168)
MAJOR
ON
test port PCSSpp sh r 2
513
17922
Speech Synthesis 
Memory Test (#166)
MINOR
ON
test port PCSSpp sh r 2
769
17664
Speech Synthesis 
DTMF Receiver 
Inquiry Test (#164)
MINOR
ON
test port PCSSpp sh r 2
1025
17670
Speech Synthesis 
SSD Inquiry Test 
(#167)
MINOR
ON
test port PCSSpp sh r 2
1281
Speech Synthesis 
DSP Tone Test (#165)
MINOR
ON
test port PCSSpp sh r 2
1537
Speech Synthesis 
Memory Test (#166)
MINOR
ON
test port PCSSpp sh r 2
1793
Speech Synthesis 
DTMF Receiver Test 
(#163)
MINOR
ON
test port PCSSpp l r 2
2049(c)
Conference Circuit 
Test (#7)
MINOR
ON
test port PCSSpp l r 2
2305
NPE Crosstalk Test 
(#6)
MINOR
ON
test port PCSSpp l r 2
3840(d)
Any
None