Maintenance Object Repair Procedures 
Page 10-1202
SW-CTL (Switch Control) 
10
f. The Aux Data for this error is not meaningful. The 1793 errors are in-line 
errors that indicate a possible problem with the interface between the 
Switch Control and the processor. The receipt of these errors causes 
Switch Control maintenance to run specific Switch Control tests. If there 
really is a problem, the Switch Control tests usually causes other errors to 
be logged. In the rare case where no other errors are logged but 1793 
errors are occurring at a high rate (more than 10 in the last hour), the 
Network Control circuit pack should be replaced at the customer’s 
convenience.
g. This error indicates bad clock detection circuitry on the Netcon circuit 
pack. Replace the Netcon circuit pack according to the control carrier 
circuit pack replacement procedures.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Switch Control Reset Test,
 for example, you may also clear errors generated from 
other tests in the testing sequence.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Switch Control Reset Test (#93)
X
D
Control Channel Interface Test (#92)
X
X
ND
Control Channel Transmission Test (#94)
X
X
ND
Destructive EPN Maintenance Board Interface Test (#325)
X
D
EPN Maintenance Board Interface Test (#324)
X
X
ND
Time of Day Clock Test (#95)
X
X
ND
Control Channel Loop Around Test (DATA-BD) (#52) (a)
X
X
ND
NPE Audit Test (DATA-BD) (#50) (a)
X
ND
Data Channel Reset Test (DATA-CHL) (#107) (b)
X
D
Data Channel Interface Test (DATA-CHL) (#108) (b)
X
D
Maintenance Loop Around Test (DATA-CHL) (#109) (b)
X
X
ND
Data Channel Crosstalk Test (DATA-CHL) (#110) (b)
X
X
ND
Data Channel Local Loop Back Test (DATA-CHL) (#111) (b)
X
X
ND
Continued on next page