Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1212
SYNC (Synchronization) 
10
SYNC (Synchronization)
The Synchronization Maintenance is composed of both hardware and software 
components and its purpose is to provide a common reference frequency for 
reliable digital communication between systems and other PBXs, COs or CPE. 
Synchronization is achieved via the use of several system components which 
include the Tone-Clock, the DS1 Interface, and the Expansion Interface circuit 
packs. Synchronization is achieved between the PPN and the EPNs via the 
Expansion Interface Link (EXP-LINK) between the networks. 
Depending on the network synchronization plan and the status of 
synchronization sources, the system timing reference may be a Tone-Clock 
circuit pack, DS1 interface circuit packs or an external Stratum 3 clock. Stratum 4 
synchronization extracts timing information directly from a DS1 reference or from 
a Tone-Clock. Stratum 3 synchronization requires the use of a Stratum 3 clock 
which provides a timing signal, derived from DS1 references, to the TN780 
Tone-Clock circuit pack. The external Stratum 3 clock is a more stable timing 
source than the Stratum 4 clock and provides 24-hour holdover in case of 
reference failures. The Stratum 3 clock has redundant components. 
Stratum 4 Synchronization
The system can be configured with primary and secondary synchronization 
references (DS1 interface circuit packs) when using Stratum 4 synchronization. 
Both references are optional (since the local oscillator can be used), and the 
secondary reference is optional if a primary is provided. If this system is the 
master for the network, then its local oscillator would be used and no DS1s would 
be used as references.
If the primary synchronization reference is not providing a valid timing signal, the 
system automatically switches to the secondary synchronization reference. If the 
secondary reference does not provide a valid timing signal or is not administered 
as a synchronization reference, a Tone-Clock circuit pack provides the system 
timing source. The system does not revert to the primary if the current reference 
is the secondary and is failing; however the system switches from the local 
oscillator to another reference when the new reference becomes available. The 
following diagram should assist in understanding Stratum 4 Synchronization 
Maintenance components within the system. This diagram depicts a possible 
Generic 1.2 configuration; DEFINITY Generic 1 does not support two EPNs, but 
the operation and maintenance described below is the same except for the 
references to multiple EPNs.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
SYNC
MAJOR
display errors
Synchronization Maintenance
SYNC
MINOR
display errors
Synchronization Maintenance
SYNC
WARNING
test synchronization
Synchronization Maintenance