Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1255
TAPE (Tape Unit) [G3iV1.1-286] 
10
!
WARNING:
DO NOT GET TAPE HEAD CLEANING SOLUTION ON THE 
CAPSTAN.
6. With a dry swab, wipe away any remaining residue from the tape head.
Tape Maintenance and Repair Procedures
This section contains commonly used procedures to resolve tape alarms. The 
following equipment may be needed to complete these procedures:
Tape Cartridges (3)
TN774 Tape Drive Circuit Pack (1)
TN773 Processor Circuit Pack (1)
TN770 Memory Circuit Pack (1)
NOTE:
In the following repair procedures, the term "main tape(s)" is used to 
refer to the tape(s) that were physically present in the tape drive(s) at 
the time the problem occurred. The "main tape(s)" should not be 
confused with the term "backup tape(s)" Backup tapes are 
physically stored outside of the tape drive(s). The term "new tape(s)" 
refers to the three new tapes that you should bring with you to the 
customer’s site; these tapes may be needed to complete the tape 
maintenance procedures. The new tapes should not have been 
used previously in the customer’s system. 
It is very important to 
keep track of these tapes.
1. Check the Error Log for power-related problems and refer to the POWER, 
DC-POWER, and CARR-POW Maintenance documentation sections. If no 
power errors exist, check the tape drive for power as follows:
If there is a problem with the 12V supplied to the tape drive, its 
yellow LED will be in a blinking mode. The 12V is supplied by the 
631DB or 676B power unit in a multicarrier cabinet system and by a 
WP91153 in the single-carrier cabinet system. This problem can 
also be caused by a failure in the 984D DC power converter on 
TN774 Tape Drive circuit pack.
If there is a problem with the five volts supplied to the tape drive, 
there is no visible way to determine this except by using the 
TN2036 Voltage Range circuit pack (see the "Troubleshooting 
Backplane Voltage Problems" section in 
 or by using the following procedure: