Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1280
TBRI-BD (TN2185 ISDN Trunk-Side BRI) 
10
LAN Receive Parity Error Counter Test (#595)
This test is nondestructive. The test reads and clears the circuit pack’s LAN 
Receive Parity Error Counter. This counter increments when it detects a parity 
error from the Packet Bus. These errors may indicate problems with a circuit 
pack, Packet Bus, or with another circuit pack on the bus. Use this test to verify 
the repair.
Table 10-439.
TEST #595 LAN Receive Parity Error Counter Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test was not received from the circuit pack within the 
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset the circuit 
pack via the 
busyout board PCSS
 and 
reset board PCSS
 
commands.
2. If the test aborts again, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1-10
FAIL
The circuit pack is still detecting errors of this type. The error code 
indicates the value of the on-board error counter.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, verify the validity of the Packet Bus. Run the 
Packet Bus maintenance test with the 
test pkt P long
 command. If any 
Packet Bus tests fail, refer to the "PKT-BUS (Packet Bus)" section for 
recommended repair procedures.
3. If the Packet Bus test passes, check the validity of the circuit pack. 
Execute a test that involves data transmission onto the Packet Bus. For 
example, the 
test port PCSSpp
 command may use the connectivity 
tests of the BRI-PORT maintenance object. If the test fails, refer to the 
repair procedures; otherwise, proceed to the next step.
4. Other circuit packs on the Packet Bus may be causing of the parity 
error. Use the 
display errors
 command to check the Error Log for 
alarmed other circuit packs. Resolve any alarms for other circuit packs 
as well. Rerun the LAN Receive Parity Error Counter Test (#595).
PASS
No errors detected.
Continued on next page