Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1294
TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
10
Receive FIFO Overflow Error 
Counter Test (#625)
This test is non-destructive.
This test reads and clears the BRI port’s Receive FIFO Overflow error counter 
maintained on the TBRI-BD circuit pack. This counter is incremented by the 
circuit pack when it detects an overflow of its receive buffers. The test passes if 
the value of the counter is 0 (that is, the error is cleared). If the counter is 
non-zero, the test fails, and the value of the counter is displayed in the Error 
Code field.
This error can occur if signaling frames are being received from the Packet Bus 
at a rate sufficient to overflow the receive buffers on the circuit pack for a port OR 
if a hardware fault is causing the receive buffers not to be emptied properly by 
the circuit pack. This test is useful for verifying the repair of the problem.
Table 10-446.
TEST #623 CRC Error Counter Test 
Error 
Code
Test 
Result
Description/ Recommendation
ANY
FAIL
This error occurs when a frame with a bad CRC is received over the 
D-Channel by the BRI board. This error is reported on a per-port basis 
when the counter goes over the threshold. This error is most likely due to a 
problem with the wiring or interference on the wiring caused by a noise 
source or no termination. It usually does not indicate a problem with the 
circuit pack.
PASS
The CRC error counter was read correctly and has a value of 0.
Continued on next page