DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1339
TDM-CLK (TDM Bus Clock) 
10
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
SAKI Reset Test
 for example, you may also clear 
errors generated from other tests in the testing sequence.
Notes:
a. Refer to “XXX-BD” for descriptions of these tests.
b. Refer to “TONE-BD” for a description of this test.
c. Refer to “TONE-PT” for descriptions of these tests.
d. This test only runs on the Standby Tone-Clock circuit pack in a Port 
Network with more than one Tone-Clock circuit pack (High or Critical 
Reliability Option). The circuit pack must be a TN780 code with firmware 
revision 2 or above, or be a TN2182.
e. Test #149 is not run on the TN2182.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
D/ND
1
SAKI Reset Test (#53) (a)
X
D
Clock Health Test (#46) (b)
X
X
ND
Control Channel Looparound Test (#52) (a)
X
X
ND
Tone Generator Crosstalk Test (#90) (c)
X
ND
Tone Generator Transmission Test (#40) (c) 
X
X
ND
Tone Generator Audit/Update Test (#41) (c)
X
X
ND
TDM Bus Clock Circuit Status Inquiry Test 
(#148)
X
X
ND
TDM Bus Clock Slip Inquiry Test (#149)(e)
X
X
ND
TDM Bus Clock PPM Inquiry Test (#150)
X
X
ND
TDM Bus Clock Parameter Update Test 
(#151)
X
X
ND
Board Type Check Test (#574)
X
X
ND
Standby Reference Health Check Test 
(#651) (d)
X
ND