Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1344
TDM-CLK (TDM Bus Clock) 
10
Set the PPM threshold at 60 PPM for TN768 and TN780. Set the PPM 
threshold at 85 PPM for TN2182.
Enable PPM threshold switching
Set the number of slips to trigger 
loss of signal
 - currently 30 per 5 
millisecond period
Enable the on-board synchronization switching algorithm (see above)
Enable holdover operation (TN2182 only).
This is not a test and will always pass without identifying or reporting any 
Tone-Clock circuit pack errors
Board Type Check Test (#574)
This test verifies that a Tone-Clock circuit pack administered with a Stratum 3 
Clock source has code TN780
Table 10-468.
TEST #151 TDM Bus Clock Parameter Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
 
ABORT
Internal System Error
 
FAIL
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
 
PASS
The Tone-Clock circuit pack parameters have been successfully updated.
Continued on next page
Table 10-469.
TEST #574 Board Type Check Test 
Error 
Code
Test 
Result
Description/ Recommendation
2012
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY
FAIL
Stratum 3 Clock Synchronization is administered for the carrier in which this 
Tone-Clock circuit pack resides, but the Tone-Clock does not have code 
TN780.
1. If the Stratum 3 Clock option is incorrectly administered, remove it.
2. Otherwise, replace the circuit pack. See 
How to Replace the 
Tone-Clock Circuit Pack in the TONE-BD section.
Continued on next page