DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1359
TIE-DS1 (DS1 Tie Trunk) 
10
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 
Interface circuit pack to ensure that the trunk’s translation is correct. Translation 
updates include the following data: trunk type (in/out), dial type, timing 
parameters, and signaling bits enabled. The port audit operation verifies the 
consistency of the current state of the trunk kept by the DS1 Interface circuit 
pack and the switch software.
PASS
The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated using other port tests and by 
examining station, trunk, or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the 
list 
config
 command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board
 command.
3. Issue the 
reset board
 command.
4. Issue the 
release busy board
 command.
5. Issue the 
test board long
 command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
check to see that there is a valid board inserted.
Table 10-473.
TEST #36 Audit and Update Test 
Error 
Code
Test 
Result
Description/ Recommendation
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page
Table 10-472.
TEST #7 Conference Circuit Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page