Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1381
TIE-TRK (Tie Trunk)
10
Tie Trunk Seizure Test (#73), Tie Trunk Dial Test
(#747). Seizure Test(#73)
(#747). Seizure Test(#73)
The Tie Trunk Seizure Test activates the M lead and checks for a response from
the external end within 10 seconds. This test is applicable only to wink start and
delay dial outgoing trunks. (For the TN2140 [G3iV2-386] circuit pack, the trunk
must also be continuous-seize-ack and discontinuous-seize-ack).
the external end within 10 seconds. This test is applicable only to wink start and
delay dial outgoing trunks. (For the TN2140 [G3iV2-386] circuit pack, the trunk
must also be continuous-seize-ack and discontinuous-seize-ack).
The Tie Trunk Dial Test seizes the trunk and outpulses a pause digit.
For a port administered as TGU or a TGE, the Seizure Test internally seizes the
trunk and outpulses a "pause." The report reports the result of the seizure attempt
uplink.
trunk and outpulses a "pause." The report reports the result of the seizure attempt
uplink.
Table 10-479.
Seizure Tests (#73, #747, #73)
Error
Code
Code
Test
Result
Description/ Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources required to run this test are not available. The trunk may
be busy with a valid call. Use the
be busy with a valid call. Use the
display trunk xx
to determine the trunk
group/member number of the port. Use the
status trunk
command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no calls), then
check the Error Log for Error Type 1025 (see Error Log table for
description of this error and required actions). The port may be locked
up. The far-end PBX may not be releasing.
description of this error and required actions). The port may be locked
up. The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1004
ABORT
(Non-TN497 circuit packs only.) The port was seized by a valid call during
the test. The test has been aborted. Use the
the test. The test has been aborted. Use the
display trunk xx
to determine
the trunk group/member number of the port. Use the
status trunk
command to determine the service state of the port. If the service state
indicates that the port is in use, the port is unavailable for certain tests.
(Refer to the "Status Commands" section in
indicates that the port is in use, the port is unavailable for certain tests.
(Refer to the "Status Commands" section in
for a full description of all possible
states.) You must wait until the port is idle before retesting.
1. Retry the command at one minute intervals a maximum of five times.
2. If the test continues to abort, and the port is not in use, escalate the
problem.
Continued on next page