Maintenance Object Repair Procedures 
Page 10-1424
TSC-ADM (Administered Temporary Signaling Connections) 
10
b. The port field in the error log contains the signaling group number for 
TSC-ADM errors.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
TSC 
Heartbeat Inquiry Test,
 for example, you may also clear errors generated
from other tests in the testing sequence.
TSC Heartbeat Inquiry Test(#604)
This test can be invoked by system technician personnel for any ADMTSC 
administered in the switch. The following table indicates the possible error 
conditions that might be encountered when the test is invoked. Most of the error 
conditions do not log an error, but switched services may take some type of 
recovery action in certain instances.
This test sends a USER INFORMATION TSC heartbeat message inquiry across 
an Administered TSC to determine if the far-end can respond to a USER 
INFORMATION TSC heartbeat message.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
TSC Heartbeat Inquiry Test (#604)
ND
Table 10-487.
TEST #604 TSC Hartbeat Inquiry Test
Error 
Code
Test 
Result
Description/ Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Reissue the 
test tsc-administered
 command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page