DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1453
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Internal Loop Around Test (#135)
This test is destructive.
The Internal Loop Around Test is run by looping the transmitted DS1 bit stream 
back into the UDS1’s board receiver. The loop occurs just before the DS1 facility 
interface. The test is highly destructive and can only be initiated by a system 
technician-demanded 
reset board PCSS
 command.
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the Internal Loop 
Around Test. When the Internal Loop Around Test is initiated, maintenance 
software sends appropriate messages to the UDS1 Interface circuit pack to start 
the test. The test uses the Tone Generator and Tone Detector to exercise a bit 
pattern consistency test for all ports. If the transmitted and received bit patterns 
on a trunk or port are different, the test fails.
When the test is complete, the maintenance software sends a stop loop around 
message to the UDS1 Interface circuit pack to put the circuit pack back into the 
normal operation mode. All trunks or ports of the UDS1 Interface circuit pack are 
restored to the in-service state after the 
release board
 command is entered.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the 
add ds1 
PCSS
 command to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.
Table 10-492.
TEST #53 SAKI Sanity Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page