Page 10-1464
UDS1-BD (UDS1 Interface Circuit Pack) 
10
Blue Alarm Inquiry Test (#139)
The Blue Alarm is a signal sent by the remote DS1 endpoint when it is 
out-of-service. The Blue Alarm Inquiry Test checks the blue alarm status of the 
remote DS1 endpoint.
When the UDS1 Interface circuit pack detects a Blue Alarm signal from the 
remote DS1 endpoint, the circuit pack will transmit a Yellow alarm to the remote 
DS1 endpoint and send a BLUE ALARM message to the maintenance software. 
When the Blue alarm is confirmed, the maintenance software places all trunks or 
ports of the UDS1 Interface circuit pack into the out-of-service state. The inquiry 
test will be run every 10 minutes until the Blue alarm is cleared.
The UDS1 Interface circuit pack takes 3 seconds to recognize and report a Blue 
alarm and 16 seconds to recognize and report the resolution of a Blue alarm. 
When the Blue alarm is cleared, the UDS1 Interface circuit pack stops 
1324
FAIL
A non-service affecting CSU Module audit failure was detected by the 
TN464F UDS1 circuit pack. No ports should be affected. No immediate 
action is required. These errors indicate that the CSU Module hardware 
may have a problem, and that it should be replaced when practical to 
avoid further deterioration.
 
PASS
DS1 signal is present and the physical link is healthy. In addition, no 
Integrated CSU errors are detected.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the 
add ds1 
PCSS
 command to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.