Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1503
UDS1-BD (UDS1 Interface Circuit Pack) 
10
CPE Loopback Jack Test (#1212)
This test is destructive.
The CPE Loopback Jack (CLJ-LB) Test causes a loopback at the CPE Loopback 
Jack and tests the building wiring connection between the TN464F DS1 board 
and the CPE Loopback Jack.
The test is highly destructive and can only be initiated by a system technician 
demanded 
test ds1-loop PCSS cpe-loopback-jack-test-begin 
[number-of-bits bit-pattern] 
command. The system technician has the choice of 
entering a loopback activation code on the command line or using the default 
code (0x47F).
All trunks or ports on the UDS1 Interface circuit pack must be busied out via the 
system technician 
busyout board
 command before running the CSJ Loopback 
Test.
The CPE Loopback Test has the TN464F UDS1 Interface circuit pack transmit a 
loopback activation code to the CPE Loopback Jack, waits up to 10 seconds for 
return of the code to verify the loopback has been established, transmits a 
framed 3-in-24 test pattern, begins counting bit errors in the received test 
pattern, and returns a PASS result to indicate that the pattern was successfully 
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the 
add ds1 
PCSS
 command to administer the UDS1 interface if it is not already 
administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board
 command.
4. Issue the 
reset board
 command.
5. Issue the 
release busy board
 command.
6. Issue the 
test board long
 command.
This should re-establish the linkage between the internal ID and the port.
Table 10-505.
TEST #1211 CSU Repeater Loopback Test  — 
Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page