Lucent Technologies lucent ユーザーズマニュアル
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1538
VC-LEV (Voice Conditioner DSP Port Level)
10
Error Log Entries and Test to Clear Values
Notes:
a. The number of VC resources in the system that are in service has fallen
below the calculated minimum value. If the number of in-service VC ports
falls below the MMCH port capacity (value entered in the Minimum
Maintenance Threshold
falls below the MMCH port capacity (value entered in the Minimum
Maintenance Threshold
VCs
field on the system parameters maintenance
form), a VEC-LEV error is logged. If this outage continues for 15 minutes a
MAJOR alarm is raised. To resolve this alarm, correct the out-of-service
problem by following the procedures below:
MAJOR alarm is raised. To resolve this alarm, correct the out-of-service
problem by following the procedures below:
1. See “VC-DSPPT” and “VC-BD” and resolve any associated alarms.
2. If a VC-LEV error/alarm exist and none has been raised against
VC-BD or VC-DSPPT maintenance objects, a VC circuit pack may
have been removed from service causing the VC-LEV error/alarm.
To resolve a VC-LEV MAJOR alarm, restore the number of VC ports
available for service to be equal to or more than the calculated port
capacity. See “Resolving VC-LEV ERRORS/ALARMS” for details.
have been removed from service causing the VC-LEV error/alarm.
To resolve a VC-LEV MAJOR alarm, restore the number of VC ports
available for service to be equal to or more than the calculated port
capacity. See “Resolving VC-LEV ERRORS/ALARMS” for details.
System Technician-Demanded Tests:
Descriptions and Error Code
Descriptions and Error Code
There are no System Technician-Demanded test for VC-LEV.
Table 10-518.
VC-LEV Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm Level
On/ Off
Board
Test to Clear Value
1 (a)
Any
None
MAJOR
OFF