DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1551
XXX-BD (Common Port Circuit Pack) 
10
XXX-BD (Common Port Circuit Pack)
The Common Port Circuit Pack Maintenance is a set of common tests used by all 
the circuit packs with the generic hardware that interfaces with the TDM bus. 
Circuit packs included in this category are listed on the following pages.
Notes:
a. All circuit pack suffixes (B,C, D, etc.) are also supported by the XXX-BD 
(Common Port Circuit Pack) Maintenance documentation.
b. The XXX-BD designation is also used in the SAT display in the case where 
reset board command
 is issued to a circuit pack type which is in 
conflict to the actual circuit pack type administered for that slot or when a 
reset board
 command is issued to an empty circuit pack slot.
When any of the Common Port Circuit Packs (except the TN754 Digital Line and 
TN758 Pooled Modem circuit packs) are physically removed from the backplane, 
no alarm is logged for approximately 11 minutes. In the case of the Digital Line 
and Pooled Modem circuit packs, approximately 21 minutes elapse before an 
alarm is logged. When a circuit pack that has been removed is alarmed, the 
alarm type is minor and is classified as an on-board alarm. The time delay 
permits maintenance activity to be performed without triggering an additional 
alarm. 
An alarm is logged only against a Common Port Circuit Pack on 
which ports have been administered.
 See the next Note.
NOTE:
In a heavily loaded system, the interval between the removal of a Common 
Port Circuit Pack and the logging of the alarm may be several minutes 
longer.
1.
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02,...etc.)
2.
Refer to the appropriate circuit pack documentation to get the correct MO name 
displayed in this field. It usually ends with BD.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
Full Name of MO
XXX-BD
2
 MAJOR
 test board PCSS
 Common Port Circuit 
Pack Maintenance 
XXX-BD
 MINOR
 test board PCSS
 Common Port Circuit 
Pack Maintenance 
XXX-BD
 WARNING
 test board PCSS
 Common Port Circuit 
Pack Maintenance