DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-1555
XXX-BD (Common Port Circuit Pack) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was 
physically removed from the system. This error type is not applicable to 
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
G3iV1-1.286 or G3iV2-386 only
Common Port Circuit Pack Maintenance Error Log Entries
Error Type
Aux 
Data
Associated Test
Alarm Level
On/Off
 Board
Test to Clear Value
0
1
0
Any
Any
Any
test board PCSS sh r 1
1(a)
0
Circuit pack 
removed or SAKI 
Sanity Test (#53)
MINOR
ON
18(b)
0
busyout board PCSS
WARNING
OFF
release board PCSS
23(c)
0
None
WARNING
OFF
36 (d)
4368
none
125 (e)
None
MINOR
ON
217
2
 (f)
0
None
WARNING
ON
257
65535
Control Channel Test 
(#52)
MINOR
ON
test board PCSS sh r 20
257 (g)
Any
None
267 (f)
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board PCSS sh
769 (i)
4358
None
1025 (j)
4363
NPE Audit Test (#50)
test board PCSS l r 20
1281 (k)
Ringing Application 
Test (#51)
MINOR
ON
test board PCSS r 2
1538 (l)
Any
None
WARNING/ 
MINOR
ON
1793 (m)
Neon Test (#220)
MINOR
ON
test board PCSS r 2
3840 (n)
Any
None
3999 (o)
Any
None