Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-4
busyout data-module 
A
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
All maintenance resources busy; try again later
busyout data-module
This command will busyout a system technician specified data module or data channel.
Help Messages
If the system technician presses 
HELP
 after entering "busyout data-module," the following 
message will be displayed:
Enter assigned extension
Error Messages
If the length or format of the extension is incorrect, the following error message will be 
displayed:
Extension invalid
If the specified extension is not administered, then the following message will be 
displayed:
Extension not assigned
If the specified extension is not a data module or a data channel, then the following 
message will be displayed:
Extension exists but assigned to a different object
If the EPN that contains the data module port is not available, the following message will 
be displayed:
EPN is not available
If the board containing the data module port is part of the SCI link, the following 
message will be displayed:
Cannot busyout/release part of SCI link
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict