Error Messages 
Page A-7
busyout modem-pool 
A
busyout modem-pool
This command will allow all members of a modem pool group to be busied out.
Help Messages
If the system technician presses 
HELP
 after entering "busyout modem-pool" the following 
message will be displayed:
 Enter assigned group number between 1-5
 Or press CANCEL to cancel the command
Error Messages
If the "busyout modem-pool" command is entered from a login for which the command is 
not valid, then the following message will be displayed:
 "busyout" is an invalid entry; please press 
HELP
If the group or member numbers entered are not in a valid format, the following message 
will be displayed:
 Identifier invalid
If the group number entered is not within the range of groups or the member number is 
not within the member range, then the following message will be displayed:
 Boards not assigned
If the specific group or member are not administered, then the following message will be 
displayed:
 Group not assigned, or group assigned but with no member
If a software fault is encountered while the command is executing, the following 
message will be displayed:
 Error encountered, can’t complete request
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
 ’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
 All maintenance resources busy; try again later