Page 8-5
busyout data-module 
8
busyout data-module
This command puts the specified data module in a maintenance busy state, even 
uninstalled data modules. No periodic or scheduled tests is performed on the 
busied out data module or data channel until it is released and no call 
processing can be executed on the data modules or over the data channels. 
Warning alarms are generated (error type 18) on each maintenance object 
busied out, so that INADS can access the state of the objects. The 
release data 
module
 command returns the specified data module (or data channel) to 
operation.
On a system with the duplication option, a busyout of a Network Control Data 
Channel (DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are 
preserved across SPE interchanges. The data channel extension must be 
released before the data channel can be brought back into service.
Output
The following example shows the output from the 
busyout data-module 300
 
command. 
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy
 (where 
xxx
 = trunk group number
and 
yyy
 = member number)
private CO line
P/xxx
 (where 
xxx
 = private CO line group 
number)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
busyout 
data-module
extension
Extension number (per 
dial-plan)
Example:
busyout data-module 31300
init
inads
craft
nms
None
None