Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-67
reset interface 
A
Error Messages
If the format of the board location is incorrect, the following error message will be 
displayed:
Port/Board invalid
If the EPN on which the specified board is not available, the following message will be 
displayed:
EPN is not available
If a board is not inserted in the specified location, then the following message will be 
displayed:
Board not assigned
If the specified board is active, the following message will be displayed:
Illegal command for active object; 
use ’set’ to switch to standby
If a reset is attempted on an invalid board in the service slot, the following message is 
displayed:
Board invalid
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
All maintenance resources busy; try again later
reset interface
Help Messages
If you press 
HELP
 after entering "reset interface," the following message displays:
Enter identifier: [cabinet(1)];carrier(A-B);position(1-2)