Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-70
reset spe-standby 
A
reset spe-standby
Help Messages
If the system technician presses 
HELP
 after entering "reset spe-standby" on a duplex SPE 
system, the following message will be displayed:
Enter standby SPE recovery level ’1’(WARM), ’2’(COLDII), 
’3’(COLDI), ’4’(REBOOT) or ’5’(EXT REBOOT)
Error Messages
If the specified level is invalid (not 1-5), the following message will be displayed:
System reset level invalid
If the standby SPE is not refreshed and the SPE Select switches are selecting the active 
SPE, the following message will be displayed:
Active SPE locked via select switches; 
Standby SPE memory not refreshed
If the standby SPE is not refreshed; the following message will be displayed:
Standby SPE memory not refreshed; use the
"refresh spe-standby" command
reset system
Help Messages
If the system technician presses 
HELP
 after entering "reset system" on a simplex SPE 
system, the following message will be displayed:
Enter system recovery level ’1’(WARM), ’2’(COLDII),
’3’(COLDI), ’4’(REBOOT), or ’5’(EXT REBOOT)
If the system technician presses 
HELP
 after entering "reset system" on a duplex 
SPE system, the following message will be displayed:
Enter system recovery level ’1’(WARM), ’2’(COLDII),
’3’(COLDI), ’4’(REBOOT),  or ’5’(EXT REBOOT)
 or ’interchange [’health-override’]’
Error Messages
If the CANCEL key is pressed after the command has been started, the following 
message is displayed: