Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-136
test shadow-link 
A
Standby SPE not available;
for information use ’status system’
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
All maintenance resources busy; try again later
test shadow-link
Help Messages
If the system technician presses 
HELP
 after entering "test shadow-link" the following 
message will be displayed:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the command entered is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, then the 
following message is displayed:
Cannot interrupt Standby SPE while entering 
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the following 
message is displayed:
Standby SPE memory not refreshed; 
use the "refresh spe-standby" command.