Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-139
test station 
A
If the standby is entering maintenance mode when this command is executed, then the 
following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the following 
message is displayed:
Standby SPE memory not refreshed;
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the SPE 
select switches when this command is executed, then the following message is 
displayed:
Active SPE locked via select switches; 
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is displayed:
Standby SPE busy with another task; 
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the following 
message is displayed:
Standby SPE not available; 
for information use "status system 1"
test station
Help Messages
If the system technician presses 
HELP
 after entering "test station" the following message 
will be displayed:
Enter extension, [’long’ or ’short’],
   [’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the format for the extension is incorrect, the following error message will be displayed:
Extension invalid
If the EPN on which the port resides is not accessible, the following message will be 
displayed:
EPN is not available
If the extension is not administered, the following message will be displayed:
Extension not assigned