DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Error Messages 
Page A-145
upgrade software 
A
If during the execution of a command a resource problem occurs that requires the user 
to restart the command, then the following message will be displayed:
Command resources busy; 
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following 
message will be displayed:
All maintenance resources busy; try again later
upgrade software
Help Messages
If the system technician presses 
HELP
 after entering "upgrade software," the following 
message is displayed:
Entry is not required
If no card-mem is loaded into the system, the following message will be displayed:
Software card-mem is not inserted in the system
If a wrong card-mem is loaded into the system, the following message will be displayed:
Incorrect card-mem loaded; insert software card-mem
If the directory information on the software card-mem is corrupted or the card-mem is 
not formatted properly, the following message will be displayed:
Software card-mem not readable; try another card-mem
If this command is in conflict with another currently executing command, then a 
message will be displayed showing the login id of the conflicting user and the conflicting 
command. The message is as follows:
’login id’:’command’ has a command conflict
If the checksum on the software card-mem is bad, the following message will be 
displayed:
Bad checksum on software card-mem; try another card-mem
If the software upgrade failed in the standby SPE, the following message will be 
displayed:
No response on upgrade status from standby SPE, command failed
If the software card-mem in the standby SPE is not replaced with a translation card-mem 
within 2 minutes, the following message will be displayed:
No translation card-mem inserted 
in the standby SPE, command aborted
If the flash text checksum failed after the standby upgrade, the following message will 
be displayed:
Standby SPE text checksum failed, command aborted