Lucent Technologies lucent ユーザーズマニュアル

ページ / 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-14
busyout port 
8
Therefore, disable the attempted re-setup of a link with the busyout command 
and the link remains intact. If the link is already down, the busyout command 
stops periodic re-setup attempts on the link.
Output
The following example is a display of the 
busyout pms-link
 command.
Field descriptions
busyout port
This command places the specified port on a circuit pack in a maintenance busy 
state. No periodic or scheduled tests are performed on the busied out port until it 
is released. When the object is maintenance busy, it is deactivated (no call 
processing activity may include the busied object). Warning alarms (error type 
18) are generated on each busied out maintenance object, so that INADS can 
determine the state of the objects. The command, 
release port,
 reactivates the 
administered port on a circuit pack at a specified location.
Port
Always blank
Maintenance Name
Name of maintenance object:
 PMS-LINK
Alt. Name
Not applicable.
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
busyout port
location
Port location:
 PPsspp
 
Examples:
busyout port 01c1101 
busyout port 02c1501
init
inads
craft
none
see below
 
 busyout pms-link                               SPE A
                             COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
             PMS-LINK                     PASS
 Command Successfully Completed