DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-18
busyout spe-standby 
8
the STBY-SPE Warning alarm are maintained across a reset system 1 (Warm 
restart) and a reset system 2 (Cold 2 restart) but are removed after all other levels 
of restart.
Feature Interactions
When a busyout of the standby SPE is performed, the fault severity level of 
the standby SPE is set to the highest possible value and memory 
shadowing is turned off. This is done to lessen the probability that the 
system switches to the standby SPE. However, in some cases a 
“spontaneous” (hard) interchange of the SPEs may still occur.
This command can be used as a mechanism to turn off memory 
shadowing of the standby SPE.
If the standby SPE is in poor health (less than optimum), memory 
shadowing can not be disabled, or communication to the standby is 
impossible a busyout of the standby SPE are still successful.
Output
The following example is a display of the 
busyout spe-standby
 command.
Field descriptions
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
busyout spe-standby
Examples:
busyout 
spe-standby
init
inads
craft
none
See below
Port
Standby SPE cabinet and carrier location (01A or 01B)
Maintenance Name
Always STBY-SPE 
Alt. Name
Always blank
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 
 busyout spe-standby                            SPE A
                           COMMAND RESULTS
   Port    Maintenance Name  Alt. Name   Result       Error Code
   01B     STBY-SPE                       PASS
 Command successfully completed