DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-33
change system-parameters maintenance 
8
Scheduled Maintenance
An automated series of maintenance tests and operations runs daily according 
to the schedule and settings specified in the following fields
Table 8-1.
Scheduled Maintenance Settings 
Start Time
Hour and minute (24-hour notation) when daily scheduled maintenance 
starts
Stop Time
The hour and minute when scheduled daily maintenance ceases. If any 
daily maintenance operations are not completed by this time, the 
system notes its stopped sequence location and includes those 
operations during the next scheduled daily maintenance.
Daily 
Maintenance
This display-only field lists the standard test series run by maintenance 
software during daily maintenance.
Save 
Translation
Indicates days that translation data in memory automatically saves to 
the Mass Storage System disk and/or tape devices during scheduled 
maintenance. The operation saves to disk, then completes a backup to 
tape. Translation data saves to both SPEs, if systems have duplicated 
SPEs. (daily, days of the week, or no) “No” prevents automatic saves.
Control 
Channel 
Interchange
Each port network has a pair of TDM busses called A and B. Each has 
a set of time slots dedicated to the control channel. One bus (at a time) 
carries the control channel in each PN. (daily, days of the week, or no) 
“No” prevents interchanges. (no)
System Clocks 
Interchange
For High and Critical Reliability systems, this option initiates a 
Tone-Clock interchange in each port network possessing duplicated 
Tone-Clock circuit packs. Each port network interchanges into the 
standby Tone-Clock for 20 seconds and then back to the 
originally-active Tone-Clock. This field indicates the days that 
interchanges occur. (daily, days of the week, or no). “No” prevents 
interchanges. (no)
The system performs a Tone-Clock interchange, activating the stand by 
Tone-Clock. After the newly-active Tone-Clock circuit pack is tested, it 
provides system clocks for its native port network. Then the system 
interchanges to the originally active Tone-Clock circuit pack. 
SPE 
Interchange
This field indicates the days SPE interchanges execute during 
scheduled maintenance, for duplicated SPE systems. (daily, days of 
the week, or no). “No” prevents scheduled interchanges. (no)
Continued on next page